Air Tightness Testing & Consultancy
Having carried out air permeability testing and consultancy on over 5,000 buildings, ranging from dwellings to educational establishments, hospitals, superstores, office buildings, factories, warehouses and cinemas, Stroma boasts a formidable degree of experience in this specialist field.
Our service offering includes:
Design Review
A comprehensive review carried out by experienced air tightness consultants who study and comment on the relevant drawn details.
Design Workshops
A simple but effective method for interrogating the air tightness strategy and key drawn details in the presence of relevant members of the project team onsite.
Training Seminars
Short training presentations aimed at both designers and construction staff which can prove invaluable in raising awareness among those most able to influence building air tightness.
Training Seminars
An inspection, prior to the test, carried out by our air tightness consultants who scrutinise the 'air barrier' details throughout the building and record all observations to be conveyed in a detailed, illustrated report.
Sample Area or ‘Comfort’ Testing
A 'dress-rehearsal' air permeability test carried out on a representative area to give an indication of how the whole building will perform and what the key air leakage issues will be.
- Sample Area or ‘Comfort’ Testing More »
Sample Area or ‘Comfort’ Testing
A 'dress-rehearsal' air permeability test carried out on a representative area to give an indication of how the whole building will perform and what the key air leakage issues will be.
- Final Acceptance Air Leakage Testing More »
Final Acceptance Air Leakage Testing
The final test includes all necessary building envelope calculations and is carried out using multi-point testing methods to ensure an even pressure distribution and, thus, reliable results. In large, complex buildings, this approach, along with our ability to depressurise the building, can be vitally important.
- Post-Test Leakage Diagnosis More »
Post-Test Leakage Diagnosis
As required if a building fails to achieve the target permeability rate upon testing, Stroma technicians generally employ localised, internal smoke testing methods to identify the main air leakage areas and the remedial works required. All findings can be presented in an illustrated report.
Stroma is UKAS accredited for carrying out air permeability tests to the required methodologies and a member of the recognised bodies i.e. the ATTMA (Air Tightness Testing & Measurement Association) and the BINDT (British Institute of Non-Destructive Testing).